Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38740184

RESUMO

Vasospastic angina is a clinical condition characterized by coronary artery spasm in angiographically normal coronary arteries. Vasospastic angina can often lead to ventricular arrhythmias, sudden cardiac death, or life-threatening bradyarrhythmias, such as high-degree atrioventricular block or asystole. We present the unusual case of a woman with depressive syndrome who underwent emergency surgery for hemostasis of a neck lesion that caused hemorrhagic shock after a suicide attempt. During surgery, the electrocardiogram revealed inferior and posterior ST-segment elevation, total atrioventricular block and torsades de pointes; the patient also suffered 4 minutes of cardiac arrest. A temporary pacemaker was placed. Coronary angiography showed right coronary artery vasospasm. Following a second similar episode after tracheostomy, a permanent pacemaker was implanted. The indication for definitive electrostimulation in such a context and the stimulation mechanisms of the carotid sinus underlying vasospasm constitute the interesting points of this clinical case. LEARNING OBJECTIVE: The indication for definitive electrostimulation in a context of recurrent episodes of high-degree atrioventricular block during vasospastic angina and the stimulation mechanisms of the carotid sinus underlying vasospasm constitute the interesting points of this clinical case.

2.
J Innov Card Rhythm Manag ; 14(4): 5410-5419, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37143577

RESUMO

Ultrasound-guided axillary vein access is an effective alternative to conventional subclavian and cephalic access for cardiac implantable electronic device implantation. The aim of this study was to compare the safety, efficacy, and radiation exposure data of the ultrasound-guided axillary approach with other conventional access techniques. The study population included 130 consecutive patients, stratified as 65 (64% male; median age, 79 years) in the study group and 65 (66% male; median age, 81 years) in the control group. We performed a retrospective not-randomized analysis by comparing ultrasound-guided axillary vein puncture with subclavian and cephalic approaches in order to test the effect on X-ray exposure, total procedure time, and complications. Significant differences were observed in terms of radiation exposure, including fluoroscopy time (median, 95 s [study group] vs. 193 s [control group]; P < .001), air kerma (median, 29 mGy [study group] vs. 55.7 mGy [control group]; P < .001), and dose-area product (median, 8219 mGy·cm2 [study group] vs. 16736 mGy·cm2 [control group]; P < .001). The median procedure time was 45 min in the study group but 50 min in the control group (P < .05). Complications occurred in 6 control group patients (1 urticaria contrast medium-related, 3 pneumothorax, 2 subclavian artery puncture) and 2 study group patients (2 axillary artery puncture). We conclude that the ultrasound-guided axillary venous approach is a fast, feasible, and safe technique for cardiac lead implantation. It allows a significant reduction in fluoroscopy time without prolonging the procedural time. This approach offers direct visualization of the vessel during the puncture, so it can be useful in patients who cannot receive contrast medium, those who require "difficult" thoracic approaches (emphysema, too much or too little fat tissue), or those on anticoagulant therapy.

3.
Eur Heart J Suppl ; 25(Suppl D): D294-D311, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37213799

RESUMO

Extended risk stratification and optimal management of patients with a permanently increased risk of sudden cardiac death (SCD) are becoming increasingly important. There are several clinical conditions where the risk of arrhythmic death is present albeit only transient. As an example, patients with depressed left ventricular function have a high risk of SCD that may be only transient if there will be a significant recovery of function. It is important to protect the patients while receiving and titrating to the optimal dose the recommended drugs that may lead to an improved left ventricular function. In several other conditions, a transient risk of SCD can be observed even if the left ventricular function is not compromised. Examples are patients with acute myocarditis, during the diagnostic work-up of some arrhythmic conditions or after extraction of infected catheters while eradicating the associated infection. In all these conditions, it is important to offer a protection to these patients. The wearable cardioverter defibrillator (WCD) is of particular importance as a temporary non-invasive technology for both arrhythmia monitoring and therapy in patients with increased risk of SCD. Previous studies have shown the WCD to be an effective and safe therapy for the prevention of SCD caused by ventricular tachycardia/fibrillation. The aim of this ANMCO position paper is to provide a recommendation for clinical utilization of the WCD in Italy, based upon current data and international guidelines. In this document, we will review the WCD functionality, indications, clinical evidence, and guideline recommendations. Finally, a recommendation for the utilization of the WCD in routine clinical practice will be presented, in order to provide physicians with a practical guidance for SCD risk stratification in patients who may benefit from this device.

4.
G Ital Cardiol (Rome) ; 24(5): 394-411, 2023 May.
Artigo em Italiano | MEDLINE | ID: mdl-37102354

RESUMO

Extended risk stratification and optimal management of patients with a permanently increased risk of sudden cardiac death (SCD) is becoming increasingly important. There are several clinical conditions where the risk of arrhythmic death is present albeit only transient. As an example, patients with depressed left ventricular function have a high risk of SCD that may be only transient when there is a significant recovery of function. It is important to protect the patients while receiving the recommended measures and drugs that may either lead or not to an improved left ventricular function. In several other conditions a transient risk of SCD can be observed even if the left ventricular function is not compromised. Examples are patients with acute myocarditis, during the diagnostic work-up of some arrhythmic conditions or after extraction of infected catheters while eradicating the associated infection. In all these conditions it is important to offer a protection to these patients. The wearable cardioverter-defibrillator (WCD) is of particular importance as a temporary non-invasive technology for both arrhythmia monitoring and therapy in patients with increased risk of SCD. Previous studies have shown the WCD to be an effective and safe therapy for the prevention of SCD caused by ventricular tachycardia/fibrillation. The aim of this ANMCO position paper is to provide a recommendation for clinical utilization of the WCD in Italy, based upon current data and international guidelines. In this document we will review the WCD functionality, indications, clinical evidence as well as guideline recommendations. Finally, a recommendation for the utilization of the WCD in routine clinical practice will be presented, in order to provide physicians with a practical guidance for SCD risk stratification in patients who may benefit from this device.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Humanos , Desfibriladores , Cardioversão Elétrica , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Arritmias Cardíacas
5.
Artigo em Inglês | MEDLINE | ID: mdl-35927601

RESUMO

BACKGROUND: The risk of complications has been shown to be lower with subcutaneous implantable defibrillator (S-ICD) than with conventional ICDs. Given the low frequency of complications, experience of how to manage them is limited. In this paper, we describe generator- and lead-related complications recorded in a series of S-ICD patients, and we propose our conservative approach to managing them. METHODS: The study cohort consisted of S-ICD patients who were referred to our institution owing to generator- or lead-related complications requiring surgical intervention. With our "shift and cover" approach, the system component involved is moved from its original position to an alternative, more protected location. In the case of the generator, this involves moving it to an intermuscular pocket. In the case of infections at the parasternal scar, the electrode sleeve is moved away from its original location, stitched, and then covered with the muscular fascia. RESULTS: Fourteen S-ICD patients were referred to our institution owing to system-related complications. Complications involved the generator in 7 cases (deep pocket infections with erosion, extrusion, or pain), the lead in 5 cases (parasternal infections at the xyphoid incision site), and both the generator and the lead in 2 cases. Complications were managed without completely removing the device and resolved in a single surgical session with no intraoperative complications. During defibrillation testing, the first shock at 65 J was effective in all patients. The shock impedance after revision was significantly lower than that measured during first implantation (59 ± 10 Ohm versus 86 ± 24 Ohm, P = 0.013). In all cases, the cosmetic result was satisfactory. No complications or recurrent infections were reported at the 12-month follow-up visit. CONCLUSIONS: The proposed conservative approach was successful in managing S-ICD complications. The revision procedure allowed to optimize the system configuration in terms of the defibrillation vector, resulting in lower shock impedance values and better device positioning.

6.
Indian Pacing Electrophysiol J ; 22(3): 161-164, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35378279

RESUMO

Subcutaneous hematoma is a complication of cardiac device implantation. In most cases, it is drained or spontaneously reabsorbed. While cases of chylothorax are rare, and cases of pseudochylothorax even rarer, previous cases of accumulation of chyliform material in the subcutaneous pockets of cardiac devices are anecdotal. We present a case of a 60-year-old man with antiphospholipids antibody syndrome and rheumatoid arthritis, who underwent dual-chamber ICD implantation in December 2020; the procedure was complicated by a pocket hematoma, which required surgical drainage. After 7 months, the man returned owing to heart failure, with evidence of the reappearance of a large swelling in the ICD pocket; this was tolerated for months by the patient and was no longer controlled. We drained 100ml of gold-colored, odorless liquid, and found no evidence of blood material in the pocket. The liquid was not pus, as culture testing proved negative for bacterial growth. Chemical-physical examination revealed elevated cholesterol concentration (704 mg/dl) and low levels of triglycerides (80 mg/dl; plasma cholesterol values were 91mg/dl, and triglycerides 48 mg/dl). Microscopic examination revealed isolated leukocytes and rare erythrocytes immersed in mucoid material; cytological analysis showed a carpet of macrophages filled with cholesterol. This evidence supports the diagnosis of pseudochyle fluid, formed by the degradation of a hematoma left intact in a closed cavity for more than 6 months. This is an extremely rare case of chyliform fluid documented in an ICD pocket.

7.
Monaldi Arch Chest Dis ; 92(2)2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34802223

RESUMO

Giant coronary artery aneurysm is an uncommon disease, treated with surgical intervention or percutaneous coil embolization. A thrombosed aneurysm can cause extrinsic compression on the cardiac chambers, with potential hemodynamic effects and may cause problems when we need to implant a cardiac device. We present a case of difficult pacemaker implantation in a patient with 3 syncopes, first-degree AV block and complete left bundle branch block on electrocardiogram. The patient presented a giant aneurysm of the right coronary artery (85 x 90 mm), thrombosed, with right atrial compression. The pacemaker implantation was hampered by the difficulty of passing the lead through the compressed right atrium; indeed, only with simultaneous echocardiographic and fluoroscopic guidance, was it possible to complete the procedure. This case demonstrates the utility of echocardiogram, in particular settings, in cardiac stimulation procedures.


Assuntos
Bloqueio Atrioventricular , Aneurisma Coronário , Marca-Passo Artificial , Bloqueio Atrioventricular/etiologia , Bloqueio de Ramo , Aneurisma Coronário/diagnóstico , Aneurisma Coronário/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Humanos , Marca-Passo Artificial/efeitos adversos
8.
Monaldi Arch Chest Dis ; 91(3)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33691391

RESUMO

Pheochromocytoma is a rare adrenal tumor characterized by the secretion of catecholamines and vasoactive peptides. It can cause a catecholaminergic storm and lead to acute coronary syndromes. We present the case of a 53-year-old man, without any medical history, who arrived to the hospital following a spinal trauma due a fall. He presents back and retrosternal pain, with a clinical status of acute pulmonary edema, sinus tachycardia with left bundle branch block, left ventricular apical ballooning with depressed systolic function. Blood tests show a very important increase of Troponin and transaminases. A contrast chest-abdomen CT highlighted a right adrenal solid mass, with a diameter of 78mm, partial capsular laceration, compression of the inferior vena cava and the hepatic parenchyma. The clinical condition of the patient rapidly worsens from a respiratory and hemodynamic point of view, with cardiogenic shock, anuria and sepsis, refractory to all the medical treatments, until the patient died. The autopsy confirmed that the abdominal mass was a pheochromocytoma, broken after the trauma suffered. The resulting catecholaminergic storm caused a myocardial ischemia with Takotsubo syndrome, with cardiogenic shock. This unfortunate case confirms the pheochromocytoma as important risk factor for the onset of Takotsubo syndrome, and the how dramatic and severe a catecholaminergic storm can be.


Assuntos
Neoplasias das Glândulas Suprarrenais , Feocromocitoma , Cardiomiopatia de Takotsubo , Neoplasias das Glândulas Suprarrenais/complicações , Neoplasias das Glândulas Suprarrenais/diagnóstico , Arritmias Cardíacas , Catecolaminas , Humanos , Masculino , Pessoa de Meia-Idade , Feocromocitoma/complicações , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico
9.
J Electrocardiol ; 58: 37-42, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31710873

RESUMO

Andersen-Tawil Syndrome (ATS) is a rare periodic paralysis with typical skeletal and neuromuscular features. Cardiac involvement may range from asymptomatic ventricular arrhythmias to sudden death. Its management remains challenging and the choice between antiarrhythmic drug therapy and implantable cardioverter defibrillator (ICD) is not simple. We present a case of ATS patient with episodes of bidirectional ventricular tachycardia, well controlled by flecainide therapy initially, which in particular conditions of fever and hypokaliemia had a cardiac arrest with ventricular fibrillation, with neurological sequelae and need of an ICD implant. A review of the therapeutic management of this disease is presented.


Assuntos
Síndrome de Andersen , Desfibriladores Implantáveis , Taquicardia Ventricular , Síndrome de Andersen/complicações , Síndrome de Andersen/diagnóstico , Síndrome de Andersen/terapia , Antiarrítmicos/uso terapêutico , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Flecainida , Humanos , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/terapia
10.
Echocardiography ; 36(10): 1936-1940, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31573719

RESUMO

Stanford type-A aortic dissection is a clinical emergency; mortality is high, and surgery is urgently required in most cases. Chronic forms of type-A dissection are rare and have a poor prognosis if not treated surgically. We present an unusual case of chronic type-A aortic dissection, with silent onset, in an oncologic patient without risk factors, which was managed conservatively and remained substantially stable during follow-up.


Assuntos
Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/terapia , Dissecção Aórtica/complicações , Dissecção Aórtica/terapia , Tratamento Conservador/métodos , Neoplasias Pancreáticas/complicações , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Doença Crônica , Ecocardiografia/métodos , Evolução Fatal , Humanos , Masculino , Tomografia Computadorizada por Raios X/métodos
11.
J Clin Ultrasound ; 46(4): 259-261, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28656711

RESUMO

We report a case of left atrial extrinsic compression caused by an esophageal food bolus in a patient presenting with acute heart failure. Transthoracic echocardiography along with contrast-enhanced CT showed evidence of esophageal dilation producing left atrial compression. Esophageal endoscopy and fragmentation of the bolus, allowing the accumulated food to descend into the stomach, produced a rapid improvement of hemodynamic and clinical status. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:259-261, 2018.


Assuntos
Ecocardiografia , Esôfago/diagnóstico por imagem , Corpos Estranhos/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Alimentos , Corpos Estranhos/complicações , Humanos
12.
Clin Cardiol ; 39(11): 640-645, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27468173

RESUMO

BACKGROUND: Because 20% to 40% of patients undergoing cardiac resynchronization therapy (CRT) do not respond to it, identification of potential factors predicting response is a relevant research topic. HYPOTHESIS: There is a possible association between right ventricular function and response to CRT. METHODS: We analyzed 227 patients from the Cardiac Resynchronization Therapy Modular Registry (CRT-MORE) who received CRT according to current guidelines from March to December 2013. Response to therapy was defined as a decrease of ≥15% in left ventricular end-systolic volume (LVESV) at 6 months. RESULTS: The tricuspid annular plane systolic excursion (TAPSE) value that best predicted improvement in LVESV (sensitivity 68%, specificity 54%) was 17 mm. Stratifying patients according to TAPSE, LVESV decreased ≥15% in 78% of patients with TAPSE >17 mm (vs 59% in patients with TAPSE ≤17 mm; P = 0.006). At multivariate analysis, TAPSE >17 mm was independently associated with LVESV improvement (odds ratio: 1.97, 95% confidence interval: 1.03-3.80, P < 0.05), together with ischemic etiology (odds ratio: 0.39, 95% confidence interval: 0.20-0.75, P < 0.01). These results were confirmed for New York Heart Association class III to IV patients (79% echocardiographic response rate in patients with TAPSE >17 mm vs 55% in patients with TAPSE <17 mm; P = 0.012). CONCLUSIONS: Baseline signs of right ventricular dysfunction suggest possible remodeling after CRT. A TAPSE value of 17 mm was identified as a good cutoff for predicting a better response to CRT in patients with both mildly symptomatic and severe heart failure.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Distribuição de Qui-Quadrado , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular
13.
Echocardiography ; 32(3): 420-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25047126

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common sustained arrhythmia, with a high recurrence rate, especially during the first months after cardioversion (CV). Few parameters have been evaluated as predictors for the maintenance of sinus rhythm (SR), with limited results. Recently total atrial conduction time (TACT) has been proposed as independent predictor of AF recurrence. The aim of this study was to investigate the prognostic value of TACT, measured using PA-TDI duration, to predict 1-year maintenance of restored SR after electrical CV. METHODS AND RESULTS: In a population of 104 patients (58 male, aged 70 ± 9) with persistent AF, submitted to external electrical CV, we performed a complete echocardiogram after restoring SR. The TACT was estimated by measuring the time delay between the onset of the P-wave in lead II of the surface electrocardiogram and the peak A'-wave on the tissue Doppler imaging (TDI) tracing of the left atrial lateral wall (so-called PA-TDI duration). After a mean follow-up of 14 ± 2 months, 34 (33%) patients had recurrent AF, whereas 70 (67%) patients maintained SR. At multivariate analysis only PA-TDI was identified as independent predictor of AF recurrence (HR 1.04; 95% CI 1.03-1.06; P < 0.001). Receiver operator characteristics curve analyses demonstrated a high degree of discrimination (area under the curve 0.923); with a cut point of 152 msec, we obtain a good diagnostic accuracy (sensitivity 91%, specificity 87%). CONCLUSION: The TACT using TDI is an independent predictor of AF recurrence and can be used to predict the maintenance of SR after external electrical CV.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Ecocardiografia Doppler/métodos , Técnicas de Imagem por Elasticidade/métodos , Cardioversão Elétrica/métodos , Eletrocardiografia/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Doença Crônica , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Condução Nervosa , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
14.
J Cardiovasc Med (Hagerstown) ; 16(11): 725-35, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25004003

RESUMO

AIMS: In the present study, we compare different echocardiographic cardiac dyssynchrony parameters, both of intraventricular and interventricular dyssynchrony, in order to predict response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS: In a population of 77 heart failure patients scheduled for CRT, we measured the interventricular mechanical delay (IVMD) and we analyzed six different parameters of intraventricular dyssynchony: the tissue Doppler imaging (TDI) septum-lateral wall delay, the systolic dyssynchrony index; the three-dimensional SD of the time to reach minimum systolic volume for 16 left ventricular segments (3D-SDI); the speckle-tracking radial, circumferential and longitudinal dyssynchrony. At 6 months of follow-up, 61 (79%) patients were responders (≤15% in left ventricular end-systolic volume). On baseline analysis, 3D-SDI, radial strain, longitudinal strain and circumferential strain and IVMD were significantly higher in responder group (10.8 ±â€Š3.9 vs. 7.6 ±â€Š1.8% for 3D-SDI; P = 0.003; 212 ±â€Š91 vs. 125 ±â€Š36 ms for radial strain, P = 0.0003; 185 ±â€Š83 vs. 134 ±â€Š53 ms for longitudinal strain, P = 0.02; 190 ±â€Š80 vs. 130 ±â€Š54 ms for circumferential strain, P = 0.006; 45 ±â€Š21 vs. 30 ±â€Š20 ms for IVMD; P = 0.01). On univariate and multivariate analysis, only IVMD was significantly associated with a complete echocardiographic response to CRT. 3D-SDI and radial strain present the better values of sensitivity and specificity, overall if associated to an evaluation of IVMD (sensitivity 76%, specificity 88%, for 3D-SDI + IVMD; sensitivity 80% and specificity 85% for radial strain + IVMD). CONCLUSION: The novel parameters, such as 3D-SDI and speckle-tracking (particularly radial strain), offer better diagnostic accuracy in identifying patients who are responders to CRT. The addition of the contemporary parameter of IVMD improves the diagnostic accuracy.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler/métodos , Ecocardiografia Tridimensional/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
15.
Echocardiography ; 31(7): E215-7, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24702723

RESUMO

Isolated supravalvular pulmonary stenosis is a rare finding, usually evidenced in the pediatric age. Here, we report a case of a 76-year-old patient with isolated, severely obstructive, pulmonary supravalvular stenosis. The peculiarity of the present case is the paucity of symptoms and lack of changes in right heart sections, despite of the importance of stenosis. The report confirms the utility of transthoracic two- and three-dimensional echocardiography and transesophageal echocardiography in the detection and quantification of this rare anomaly.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Estenose da Valva Pulmonar/diagnóstico por imagem , Idoso , Diagnóstico Diferencial , Humanos , Masculino , Doenças Raras
16.
G Ital Cardiol (Rome) ; 14(6): 445-55, 2013 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-23748541

RESUMO

Accidental or deliberate ingestion of poisonous herbs has become an increasingly common phenomenon over the last years. From existing literature data and case reports from emergency room visits or poison control centers, an overview is presented of the potential cardiotoxic manifestations following intoxication by wild herbal plants of the territory. The effects of the consumption of cardiac glycoside-containing plants (e.g., digitalis) are discussed along with tachyarrhythmias induced by Aconitum napellus L., Atropa belladonna L., Mandragora officinarum L. or Ephedra distachya L. herbs, and hypertensive crises associated with licorice abuse. For each plant, a brief historical and botanical background is provided, focusing on pathophysiology of intoxication and cardiotoxic effects on the basis of the most recent literature. Finally, medical management of intoxication, from both a general and cardiological viewpoint, is reviewed.


Assuntos
Cardiopatias/induzido quimicamente , Plantas Tóxicas/toxicidade , Cardiopatias/diagnóstico , Humanos
17.
Scand J Clin Lab Invest ; 72(5): 355-62, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22486807

RESUMO

BACKGROUND: Fibrinogen elevation is associated with a worse prognosis in patients with acute coronary syndrome (ACS). The aim of the present study was to assess the prognostic value of increased fibrinogen concentrations in ST-elevation myocardial infarction (STEMI) patients treated with primary percutaneous coronary intervention (PCI). METHODS: A total of 428 STEMI patients treated with primary PCI were retrospectively selected (median age: 62 years; 82.5% males) from a continuous case series of 832 ACS patients. Plasma fibrinogen concentrations were measured before PCI and after 24, 48, and 72 hours. In the 4-year follow-up, one major adverse cardiovascular event (MACE) occurred in 111 patients (40%): 17 re-STEMI (7%), 64 re-PCI (22%), 22 cardiac deaths (7%), and eight non ST-elevated acute coronary syndromes (NSTEACS, 4%). RESULTS: According to the reference change value, fibrinogen concentrations increased in 25% of patients at 24 h, 64% at 48 h and 19% at 72 h. Only fibrinogen concentrations at 48 h showed a mild association with overall MACEs (p = 0.036): the risk increased, starting from a concentration of 4 g/L. However a further multivariate model did not confirm any prognostic value. No association with specific MACEs emerged. CONCLUSIONS: In contrast to NSTEACS patients, fibrinogen concentrations increased slightly in STEMI patients after primary PCI, however, they were not as prognostic as for MACEs.


Assuntos
Fibrinogênio/metabolismo , Infarto do Miocárdio/sangue , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Prognóstico , Modelos de Riscos Proporcionais , Risco
18.
Echocardiography ; 29(6): E141-4, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22329527

RESUMO

Prosthetic valve endocarditis (PVE) due to staphylococcus aureus is associated with high morbidity and mortality. Paravalvular abscess formation is a common complication of PVE at the aortic position, but fistula formation is rarely seen. The transesophageal echocardiography is the "gold-standard" exam to detect PVE. We present a case of a 69-year-old patient with prosthetic aortic valve endocarditis, paravalvular abscess, and fistula in right atrium, where the diagnosis was made with three-dimensional transthoracic echocardiography, without transesophageal evaluation.


Assuntos
Abscesso/diagnóstico por imagem , Aorta/anormalidades , Fístula Artério-Arterial/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Átrios do Coração/anormalidades , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Abscesso/etiologia , Idoso , Aorta/diagnóstico por imagem , Fístula Artério-Arterial/etiologia , Diagnóstico Diferencial , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Infecções Relacionadas à Prótese/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...